Porcine Epidemic Diarrhea Virus Antigen Rapid Test

SKU : VD511
PEDV Ag Test

จำนวน
รายละเอียดสินค้า

Product Description
Porcine Epidemic Diarrhea Virus Antigen Rapid Test

Short Introduction
Porcine Epidemic Diarrhea Virus (PEDV) is one cause of the enteritis in piglets. It can cause high mortality rate especially in young pigs. The Porcine Epidemic Diarrhea Virus Antigen Rapid Test is a lateral flow immunochromatographic assay for the qualitative detection of PEDV antigen (PEDV Ag) in pig's feces or vomit specimen.

Product NamePorcine Epidemic Diarrhea Virus Antigen Rapid Test
Specimenfeces or vomit
Assay TimeVD511
MOQ800 test kits
Delivery time1 week after Get payment
Packing10 test kits/Packing box
Storage Temperature2-30°C,DO NOT FREEZE. Do not store the test kit in direct sunlight.
Shelf Life18 months
Production Capacity1 Million/Day
PaymentT/T, Western Union, Paypal

 

Principle
The Porcine Epidemic Diarrhea Virus Antigen Rapid Test is based on sandwich lateral flow immunochromatographic assay. The test device has a testing window for the observation of assay running and result reading. The testing window has an invisible T (test) zone and a C (control) zone before running the assay. When the treated sample was applied into the sample hole on the device, the liquid will laterally flow through the surface of the test strip and react with the pre-coated monoclonal antibodies. If there is PEDV antigen in the specimen, a visible T line will appears. The C line should always appear after a sample is applied, which indicates a valid result. By this means, the device can accurately indicate the presence of PEDV antigen in the specimen.


Feature 
1. Easy opertaion 
2. Fast read Result
3. High Sensitivity and accuracy 
4. Reasonable price and high quality 

TEST PROCEDURE - Collect pig or piglet's feces with the cotton swab from the anus or from the ground.
- Insert the swab into the provided assay buffer tube. Agitates it to get efficient sample extraction.
- Take out the test device from the foil pouch and place it horizontally.
- Suck the treated sample extraction from the assay buffer tube and place 3 drops into the sample hole "S" of the test device.
- Interpret the result in 5-10 minutes. Result after 10 minutes is considered as invalid.


เว็บไซต์นี้มีการใช้งานคุกกี้ เพื่อเพิ่มประสิทธิภาพและประสบการณ์ที่ดีในการใช้งานเว็บไซต์ของท่าน ท่านสามารถอ่านรายละเอียดเพิ่มเติมได้ที่ นโยบายความเป็นส่วนตัว และ นโยบายคุกกี้
เปรียบเทียบสินค้า
0/4
ลบทั้งหมด
เปรียบเทียบ
Powered By MakeWebEasy Logo MakeWebEasy