ชุดตรวจโรคปากและเท้าเปื่อย(FMD) สำหรับแกะ (Non-structural Protein 3ABC)-Ovine Foot And Mouth Diseases Virus Non Structural Protein 3Abc Antibody Fmd Nsp Ab Test

SKU : VD526
FMD NSP Ab

จำนวน
รายละเอียดสินค้า

Product Description
Ovine Foot and Mouth Disease Virus Non-Structural Protein Antibody Rapid Test

Short Introduction
The Ovine Foot and Mouth Disease Virus Non-Structural Protein Antibody Rapid Test (FMD NSP Ab) is a lateral flow immunochromatographic assay for the qualitative detection of infected viral FMDV antibodies in sheep's serum, plasma. FMDV 3ABC recombinant was applied in this assay.

Product NameFMD NSP Ab Rapid Test
Specimenserum, or plasma specimen.
Assay Time5-10 minutes
Part No.VD526
MOQ800 test kits
Delivery time1 week after Get payment
Packing10 test kits/Packing box
Storage Temperature2-30°C,DO NOT FREEZE. Do not store the test kit in direct sunlight.
Shelf Life18 months
Production Capacity1 Million/Day
PaymentT/T, Western Union, Paypal

 

Principle
The FMD NSP Ab Rapid Test is based on sandwich lateral flow immunochromatographic assay. The test device has a testing window for the observation of assay running and result reading. The testing window has an invisible T (test) zone and a C (control) zone before running the assay. When the treated sample was applied into the sample hole on the device, the liquid will laterally flow through the surface of the test strip and react with the pre-coated FMDV 3ABC antigens. If there are anti-3ABC antibodies in the specimen, a visible T line will appears. The C line should always appear after a sample is applied, which indicates a valid result. By this means, the device can accurately indicate the presence of FMDV 3ABC antibodies in the specimen.

Feature 
1. Easy opertaion 
2. Fast read Result
3. High Sensitivity and accuracy 
4. Reasonable price and high quality 

TEST PROCEDURE - Collect sheep's fresh whole blood, and get the serum or plasma specimen for use. Immediately apply the testing once collected the specimen.
- Take out the test device from the foil pouch and place it horizontally.
- Place 2-3 drop (around 70-100uL) of serum or plasma specimen into the sample hole. Start timer and wait for result.
- Interpret the result in 5-10 minutes. Result after 15 minutes is considered as invalid.